Pure Air 10-20 Natural Cleaner - Models available: Mobile on castors or Portable
Hi-Performance, efficient natural air cleaning, odour neutralising and sterilising system with automatic conversion of ozone residue to oxygen
Declaration of Conformity
Model No. Pure Air 10-20 Natural Cleaner
This unit fully complies with CE rules of EMC regulations:
EN 61000-61, EN 61000-62, EN 61010-1, EN 5501.
Low Running costs of only 1.82p per hour!
based on power rating of 120W and 1kWh = 13p
Total Working Cycles Times, Generation, Dwell, and Destruct Times for approx. room sizes and does not include the initial 30-second safety delay and 1-minute plate drying time.
Total Cycle | Ozone Generation (Mins) | Dwell Time | Ozone Destruct (Mins) | Room Size |
15 | 3 | 2 | 10 | 30 |
30 | 7 | 2 | 21 | 50 |
45 | 15 | 2 | 28 | 70 |
60 | 25 | 2 | 33 | 100 |
120 | 60 | 5 | 55 | 150 |
The Standard Menu Working Cycle table serves as a guide. To achieve the desired result for rooms or spaces that are more heavily contaminated, you may need to run longer cycles for increased Ozone levels in the room.
Pure Air 10-20 Ozone Generator
Mains supply UK and Europe: 230V/ 50Hz / 140W. For other countries or mains supplies, please contact Ozone Clean Air Ltd.
Noise level: below 61dBA
Ozone Output: 10g/hour or 20g/hour (10,000 mg/h or 20,000 mg/h) typical.
Operation: Selectable automatic ozone activation & deactivation cycles timing
– 5 fully automated working cycle times of ozone production and destruction: 15, 30, 45, 60, 120 minutes
– 5 fully automated cycles of ozone residue destruction / removal: 15, 30, 45, 60, 120 minutes, when additional removal of ozone residue is desired in rooms with heavy soft furnishings.
Effective destruct filter area: 1,300cmsq
Effective destruct filter volume: 3,900cm cube
Control Panel: Touch Keypad with operator LED prompts.
Safety: Mains fuse 3.5A ceramic slow, 20 x 5mm. 30 second start-up delays.
The Pure Air 10-20 provides audio and visual feedback of its operational status using LED indicators and an audio sounder. Air vents are protected by a fine stainless steel mesh.
Internal fan is thermally and against stall protected and provided with a safety finger guard.
Operating temperature of the enclosure is virtually that of ambient temperature.
Service: No consumable materials. Removable ozone destruct filter cartridge.
Inbuilt service hour meter. 500 hour or Annual service inspection intervals are recommended.
In-built test of key functional parts via the control keyboard.Dimensions: 420 x 265 x 225mm
Ozone Outlet: Vent on top cover.
Weight: 9.5 kg approx.
Shipping weight: 10.5 kg approx.
Construction: Commercial grade, Lightweight aluminium
Certification: CE, RoHS.